demorgan law by NOR

Avrajit
Avrajit sardar
Created on Jan 1, 2021 0 0 3
 demorgan law by NOR
100%

Integrated Circuits Used

Procedure

  1. Add IC 74LS02 into ICBase-2 (74LS02).
  2. Add IC 74LS08 into ICBase-3 (74LS08).
  3. Add IC 74LS04 into ICBase-4 (74LS04).
  4. Connect Output-7 to Pin-1 (Output) of ICBase-2 (74LS02).
  5. Connect Input-9 to Pin-2 (Input) of ICBase-2 (74LS02).
  6. Connect Pin-3 (Input) of ICBase-2 (74LS02) to Input-8.
  7. Connect GND Port to Pin-7 (Ground) of ICBase-2 (74LS02).
  8. Connect VCC Port to Pin-20 (VCC) of ICBase-2 (74LS02).
  9. Connect Pin-1 (Input) of ICBase-4 (74LS04) to Input-3.
  10. Connect Pin-1 (Input) of ICBase-3 (74LS08) to Pin-2 (Output) of ICBase-4 (74LS04).
  11. Connect Pin-3 (Input) of ICBase-4 (74LS04) to Input-2.
  12. Connect Pin-2 (Input) of ICBase-3 (74LS08) to Pin-4 (Output) of ICBase-4 (74LS04).
  13. Connect Output-3 to Pin-3 (Output) of ICBase-3 (74LS08).
  14. Connect GND Port to Pin-7 (Ground) of ICBase-4 (74LS04).
  15. Connect VCC Port to Pin-20 (VCC) of ICBase-4 (74LS04).
  16. Connect VCC Port to Pin-20 (VCC) of ICBase-3 (74LS08).
  17. Connect GND Port to Pin-7 (Ground) of ICBase-3 (74LS08).