Mod 12 correct - Copy

Skand
Skand Tandon
Created on Feb 24, 2021 0 0 1
Mod 12  correct - Copy
100%

Integrated Circuits Used

Procedure

  1. Connect VCC Port to Pin-5 (VCC) of ICBase-2 (74LS93).
  2. Connect GND Port to Pin-16 (Ground) of ICBase-2 (74LS93).
  3. Connect Output-3 to Pin-18 (Output) of ICBase-2 (74LS93).
  4. Connect Output-4 to Pin-15 (Output) of ICBase-2 (74LS93).
  5. Connect Output-5 to Pin-14 (Output) of ICBase-2 (74LS93).
  6. Connect Pin-17 (Output) of ICBase-2 (74LS93) to Output-6.
  7. Connect Clock port of 1Hz frequency to Pin-20 (Input) of ICBase-2 (74LS93).
  8. Connect Pin-1 (Input) of ICBase-2 (74LS93) to Pin-18 (Output) of ICBase-2 (74LS93).
  9. Add IC 74LS93 into ICBase-2 (74LS93).
  10. Connect Pin-3 (Input) of ICBase-2 (74LS93) to Pin-17 (Output) of ICBase-2 (74LS93).
  11. Connect Pin-2 (Input) of ICBase-2 (74LS93) to Pin-17 (Output) of ICBase-2 (74LS93).
  12. Connect Pin-2 (Input) of ICBase-2 (74LS93) to ICBase-2 (74LS93).