Experiment 2

Sindhu
Sindhu SG
Created on Feb 1, 2021 0 0 2
Experiment 2
100%

Integrated Circuits Used

Procedure

  1. Add IC 74LS11 into ICBase-3 (74LS11).
  2. Add IC 74LS04 into ICBase-2 (74LS04).
  3. Connect GND Port to Pin-7 (Ground) of ICBase-3 (74LS11).
  4. Connect GND Port to Pin-7 (Ground) of ICBase-2 (74LS04).
  5. Connect Pin-20 (VCC) of ICBase-3 (74LS11) to VCC Port.
  6. Connect VCC Port to Pin-20 (VCC) of ICBase-2 (74LS04).
  7. Connect Input-5 to Pin-1 (Input) of ICBase-3 (74LS11).
  8. Connect Pin-1 (Input) of ICBase-2 (74LS04) to Input-6.
  9. Connect Pin-2 (Input) of ICBase-3 (74LS11) to Pin-2 (Output) of ICBase-2 (74LS04).
  10. Connect Pin-19 (Input) of ICBase-3 (74LS11) to Input-7.
  11. Connect Output-0 to Pin-18 (Output) of ICBase-3 (74LS11).