New Circuit

vaibhav kulkarni
vaibhav kulkarni
Created on Apr 21, 2026 0 0 2
New Circuit
100%

Integrated Circuits Used

Procedure

  1. Add IC 74LS90 into ICBase-4 (74LS90).
  2. Connect Manual clock Port to Pin-1 (Input) of ICBase-4 (74LS90).
  3. Connect VCC Port to Pin-3 (Input) of ICBase-4 (74LS90).
  4. Connect VCC Port to Pin-5 (VCC) of ICBase-4 (74LS90).
  5. Connect Seven segment display 1 to Pin-14 (Output) of ICBase-4 (74LS90).
  6. Connect Seven segment display 1 to Pin-15 (Output) of ICBase-4 (74LS90).
  7. Connect GND Port to Pin-16 (Ground) of ICBase-4 (74LS90).
  8. Connect Seven segment display 1 to Pin-17 (Output) of ICBase-4 (74LS90).
  9. Connect Seven segment display 1 to Pin-18 (Output) of ICBase-4 (74LS90).
  10. Add IC 74LS00 into ICBase-3 (74LS00).
  11. Connect GND Port to Pin-7 (Ground) of ICBase-3 (74LS00).
  12. Connect VCC Port to Pin-20 (VCC) of ICBase-3 (74LS00).