DOWN counter by 74LS191

DEEPAK
DEEPAK KAKADE
• Created on Dec 15, 2024 • 0 • 0 • 1
DOWN counter by 74LS191
100%

Integrated Circuits Used

Procedure

  1. Add IC 74HC191 into ICBase-1 (74HC191).
  2. Connect VCC Port to Pin-20 (VCC) of ICBase-1 (74HC191).
  3. Connect GND Port to Pin-8 (Ground) of ICBase-1 (74HC191).
  4. Connect Output-0 to Pin-3 (Output) of ICBase-1 (74HC191).
  5. Connect Output-1 to Pin-2 (Output) of ICBase-1 (74HC191).
  6. Connect Pin-6 (Output) of ICBase-1 (74HC191) to Output-2.
  7. Connect Output-3 to Pin-7 (Output) of ICBase-1 (74HC191).
  8. Connect Input-1 to Pin-1 (Input) of ICBase-1 (74HC191).
  9. Connect Input-0 to Pin-19 (Input) of ICBase-1 (74HC191).
  10. Connect Input-2 to Pin-14 (Input) of ICBase-1 (74HC191).
  11. Connect Input-3 to Pin-13 (Input) of ICBase-1 (74HC191).
  12. Connect GND Port to Pin-4 (Input) of ICBase-1 (74HC191).
  13. Connect Pin-17 (Output) of ICBase-1 (74HC191) to Pin-15 (Input) of ICBase-1 (74HC191).
  14. Connect Clock port of 1Hz frequency to Pin-18 (Input) of ICBase-1 (74HC191).
  15. Connect VCC Port to Pin-5 (Input) of ICBase-1 (74HC191).