New Circuit

Subhadip
Subhadip Das
Created on Jan 21, 2026 0 0 1
New Circuit
100%

Integrated Circuits Used

Procedure

  1. Add IC 74LS02 into ICBase-1 (74LS02).
  2. Connect Pin-20 (VCC) of ICBase-1 (74LS02) to VCC Port.
  3. Connect Pin-7 (Ground) of ICBase-1 (74LS02) to GND Port.
  4. Connect Pin-2 (Input) of ICBase-1 (74LS02) to Input-0.
  5. Connect Pin-3 (Input) of ICBase-1 (74LS02) to Input-0.
  6. Connect Pin-5 (Input) of ICBase-1 (74LS02) to Input-1.
  7. Connect Pin-6 (Input) of ICBase-1 (74LS02) to Input-1.
  8. Connect Pin-14 (Input) of ICBase-1 (74LS02) to Input-2.
  9. Connect Pin-15 (Input) of ICBase-1 (74LS02) to Input-2.
  10. Connect Pin-1 (Output) of ICBase-1 (74LS02) to Pin-14 (Input) of ICBase-1 (74LS02).
  11. Connect Pin-4 (Output) of ICBase-1 (74LS02) to Pin-15 (Input) of ICBase-1 (74LS02).
  12. Connect Output-0 to Pin-16 (Output) of ICBase-1 (74LS02).