100%

Integrated Circuits Used

Description

4 : 1 MUX

Procedure

  1. Add IC 74LS151 into ICBase-1 (74LS151).
  2. Connect Output-1 to Pin-6 (Output) of ICBase-1 (74LS151).
  3. Connect Output-0 to Pin-5 (Output) of ICBase-1 (74LS151).
  4. Connect VCC Port to Pin-20 (VCC) of ICBase-1 (74LS151).
  5. Connect GND Port to Pin-8 (Ground) of ICBase-1 (74LS151).
  6. Connect Pin-4 (Input) of ICBase-1 (74LS151) to Input-0.
  7. Connect Pin-3 (Input) of ICBase-1 (74LS151) to Input-1.
  8. Connect VCC Port to Pin-18 (Input) of ICBase-1 (74LS151).