Shift register using 74194

Parthiv
Parthiv Vinoy
Created on Sep 29, 2021 0 0 1
Shift register using 74194
100%

Integrated Circuits Used

Procedure

  1. Connect Input-15 to Pin-1 (Input) of ICBase-1 (74LS194).
  2. Connect Input-13 to Pin-2 (Input) of ICBase-1 (74LS194).
  3. Connect Input-11 to Pin-3 (Input) of ICBase-1 (74LS194).
  4. Connect Input-10 to Pin-4 (Input) of ICBase-1 (74LS194).
  5. Connect Input-9 to Pin-5 (Input) of ICBase-1 (74LS194).
  6. Connect Input-8 to Pin-6 (Input) of ICBase-1 (74LS194).
  7. Connect Input-6 to Pin-7 (Input) of ICBase-1 (74LS194).
  8. Connect Pin-8 (Ground) of ICBase-1 (74LS194) to GND Port.
  9. Connect Input-0 to Pin-13 (Input) of ICBase-1 (74LS194).
  10. Connect Input-1 to Pin-14 (Input) of ICBase-1 (74LS194).
  11. Connect VCC Port to Pin-20 (VCC) of ICBase-1 (74LS194).
  12. Connect Output-11 to Pin-19 (Output) of ICBase-1 (74LS194).
  13. Connect Output-10 to Pin-18 (Output) of ICBase-1 (74LS194).
  14. Connect Output-9 to Pin-17 (Output) of ICBase-1 (74LS194).
  15. Connect Output-8 to Pin-16 (Output) of ICBase-1 (74LS194).
  16. Connect Manual clock Port to Pin-15 (Input) of ICBase-1 (74LS194).
  17. Add IC 74LS194 into ICBase-1 (74LS194).