Expt 2 P2

Mahesh
Mahesh Gokhale
Created on Aug 17, 2021 0 0 2
Expt 2 P2
100%

Integrated Circuits Used

Description

MUX

Procedure

  1. Add IC 74LS153 into ICBase-1 (74LS153).
  2. Connect GND Port to Pin-8 (Ground) of ICBase-1 (74LS153).
  3. Connect VCC Port to Pin-20 (VCC) of ICBase-1 (74LS153).
  4. Add IC 74LS04 into ICBase-2 (74LS04).
  5. Connect GND Port to Pin-7 (Ground) of ICBase-2 (74LS04).
  6. Connect VCC Port to Pin-20 (VCC) of ICBase-2 (74LS04).
  7. Connect VCC Port to Pin-6 (Input) of ICBase-1 (74LS153).
  8. Connect GND Port to Pin-5 (Input) of ICBase-1 (74LS153).
  9. Connect Pin-3 (Input) of ICBase-1 (74LS153) to Input-2.
  10. Connect Pin-1 (Input) of ICBase-2 (74LS04) to Input-2.
  11. Connect Pin-4 (Input) of ICBase-1 (74LS153) to Pin-2 (Output) of ICBase-2 (74LS04).
  12. Connect Pin-2 (Input) of ICBase-1 (74LS153) to Input-1.
  13. Connect Pin-18 (Input) of ICBase-1 (74LS153) to Input-0.
  14. Connect GND Port to Pin-1 (Input) of ICBase-1 (74LS153).
  15. Connect Output-0 to Pin-7 (Output) of ICBase-1 (74LS153).